Senva CT1RA3X : Recessed Wall CO2 Sensor, 0 2000 (Default) or 0 5000/10000 ppm (Selectable), 420mA/05VDC/010VDC Output, Integrated SetPoint Relay, ABS Plastic Enclosure, 7year Limited Warranty, Made in USA. Back.
Adjustable for ranges of 2000, 5000, or 10,000 ppm CO2 Field replaceable NDIR element Dual 3wire 420mA and 05/010V (selectable) Rugged gasketed enclosure. Integrated display and pushbutton menus for field selectable scale, calibration, and operational modes; Dual 420mA and 05V/010V output (jumper selectable) Integrated highreliability solidstate setpoint relay is ideal for direct ...
carbon dioxide c02 co2 transmitter 5000 PPM 4 20mA output. Threewire 4~20mA Current output. 4 ~ 20mA R. High precision CO2 sensor. Signal output :. Probe material Refer to GB/T 13926 , EN6100062 , EN6100063. V0 refer toUL94. IP65 refer to IEC 529 – 598/GB 700 – 86/ GB 4208.. Condition:: New: A brandnew, unused, unopened, undamaged item in its original packaging (where ...
CO112 Capteur de CO2 avec sortie active 010V ou 420mA. Détecteur de dioxyde de carbone avec sorties 010V ou 420mA (à configurer en déplaçant un commutateur interne). Plage de mesure de 0 à 5000 ppm. Alimentation en 24V CA ou CC. Plusieurs versions : avec ou sans écran LCD, avec sonde d''ambiance ou déportée à l''arrière du boîtier.
Affordable price hydrogen gas detector for sale. Optional measuring range 01000/2000/5000 ppm, max 10000 ppm, supports remote control with output signal 420mA or RS485, high accuracy 3% H2 gas leak detector for hydrogen concentration detecting with …
C3 standard infrared CO2 sensor with 420mA or transmitter for ppm ranges. Measuring Ranges: Standard: 03000 ppm. Optional: 05000 ppm, 06000 ppm, 010,000 ppm, 020,000 ppm or 030,000 ppm CO2. Sensor sizes: Standard industrial C3 infrared CO2 sensor. Part no: 2112B7000. Power supply: 24Vdc Output: 420mA or
CO2/Temp Duct Sensor. LCD display with field calibration menu. Adjustable for ranges of 2000, 5000, or 10,000 ppm CO2. Integrated setpoint relay. Field replaceable NDIR element. Integrated display and pushbutton menus for field selectable scale, calibration, and operational modes. Dual 420mA and 05V/010V output (jumper selectable)
CO2: 0 to 2000, 0 to 5000, or 0 to 10000 ppm (depending on model). Accuracy: CO2: ±40 ppm ±3% of reading. Temperature Dependence: ±8 ppm/°C at 1100 ppm. NonLinearity: 16 ppm. Pressure Dependence: % of reading per mm of Hg. Response Time: 300 s (T63). Temperature Limits: 32 to 122°F (0 to 50°C). Humidity Limits: 10 to 95% RH (noncondensing). Power Requirements: 16 to 35 …
The standard GGCO2 sensor comes equipped with a corrosion proof enclosure and adaptive temperature control designed to work anywhere. With only one sensor for any application; designing, ordering, and maintaining your CO2 monitoring system is easy. The 0/3percnt; range (0/30,000 ppm) is broad enough to handle OSHA''s recommended alarm levels (percnt; and percnt;), providing …
CO2 Measurement Range . 0 to 2000 ppm (0 ppm = 0 V, 4 mA; 2000 ppm = 10/5V, 20 mA) CO2 Accuracy Single Channel . 4001250 ppm ±30 ppm or 3% of reading (whichever is greater) 12505000 ppm ±5% of reading + 30ppm *Tolerance based on span gas of ±2% . Power Supply Requirements . 1830V AC RMS, 50/60 Hz . Power Consumption . W at nominal ...
The CTX300 transmitter is a fixed gas detector, with a 420 mA analog linear output for the detection of toxic, refrigerant (refrigerant leak), solvent, or asphyxiating (CO2, Helium or lack of oxygen) a very large number of interchangeable available sensor, the CTX 300 gas transmitter covers most tertiary or industrial applications in safe areas, not classified as ATEX. Optionally a ...
0 2000 ppm | 0 5000 ppm: CO2 Measurement Repeatability : ±20 ppm ±1% of measured value: CO2 Measurement Resolution : 1 ppm: CO2 Sensor Type : NDIR: Color : Cloud White: Dimension Depth : " (61 mm) Dimension Height : " (78 mm) Dimension Probe Diameter : 1" ( mm) Dimension Probe Length : " (198 mm) Dimension Width : " (170 mm) Display Resolution : 2 Rows x 8 Characters ...
0 5000 ppm CO2 (02000 ppm is factory default range) Meaurement accuracy . ± 5% of reading or ± 75 ppm. Repeatability . ± 20 ppm . Recommended calibration interval . 5 Years . Warm up time . Less than 1 minute . Operating temperature range . 0 50 ° C . Operating humidity range . 5 90% RH, (non condensing) Storage temperature 30 to + 60 ° C . Power requirements . 18 28VRMS AC, 18 ...
OUTPUT 4/20 mA linear for 0/2000 ppm or 0/5000 ppm or 0/7000 ppm Connecting DESIGNATION CO LOR Supply + RED Supply – BLUE Signal 4/20 mA WHITE Maintenance For optimal detection, it is necessary to protect the sensor during treatment. Title: Capteur CO2_GB Author: tobillaud Created Date: 5/16/2018 4:43:59 PM ...
Dual Analog 3wire 420mA and 05V/010V (2) (jumper) Output scaling 0 2000 or 0 5000 ppm (selectable) Digital Setpoint Output Programmable Solidstate, 1A 30VAC/DC, Sensor Performance Type Nondispersive Infrared (NDIR) Accuracy ±40ppm, ±3% of reading Response time 2 minutes to 90% reading Output update rate 3 seconds
Capteur capacitif en polymère . Plage de mesure du CO2. 0 à 2000 ppm (0 ppm = 0 V, 4 mA; 2000 ppm = 10 / 5V, 20 mA) Précision CO2 monocanal. 4001250 ppm ± 30 ppm ou 3% de la lecture (la valeur la plus élevée étant retenue) 12505000 ppm ± 5% de la lecture + 30 ppm * Tolérance basée sur un gaz d''étalonnage de ± 2% . Exigences d ...
The concentration of carbon dioxide (% usuallly) is related to daily life. Recently, there’s a study showing that the atmospheric CO2 content has reached % (385 ppm) which is the highest value since million years. The raise of atmospheric CO2 content to some extent results in global climate change. How to accurately measure the carbon dioxide gas concentration is becoming a ...
Carbon dioxide c02 co2 transmitter 5000 PPM 4 20mA output is applicable to all kinds of intelligent buildings , HVAC systems,for example: the airport, station, subway station, pharmaceutical factory, museum, intelligent building and the gym product uses the principle of infrared gas sensor, a variety of output signals is optional, it can satisfy the different measurement environments ...
CO2 SENSOR, WALL, ±5%, 05000 PPM, 420 MA, 010 VDC, 1 RELAY, LCD, PLASTIC ENCLOSURE, NO RATING. product family features . 24 VAC/VDC power ; 010 VDC or 420 mA analog output, jumper selectable; 05000 ppm CO2 range; Wallmount and ductsampling versions; Isolation of output and power; Compact, attractive enclosure; Optional control relay with adjustable setpoint; Simple single …
CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Relative humidity: 0 to ; Temperature: 32 to 122°F (0 to 50°C). Accuracy: ±40 ppm + 3% of reading (CO2); ±2% (RH). Temperature Dependence: ±8 ppm/ °C at 1100 ppm. NonLinearity: 16 ppm. Pressure Dependence: % of reading per mm of Hg. Response Time: 2 minutes for 99% step change. Temperature Limits: 32 to 122°F (0 to 50°C ...
4 C 3 H 8 NH 3 CL 2 0100 ppm 0250 ppm 0250 ppm 010 ppm 01000 ppm 02000 ppm 05000 ppm 010,000 ppm 050% 050% 0 HR 050% LIE 050 ppm 050% LIE 050% LIE 0250 ppm 010 ppm 02 02250 02nulH2250 14 01 15 155000 1510000 13 20 22 23 25 08 16 05 06 04 17 Gaz Échelle Type 60 A B A=1 relais 2 sortie 420ma B= 2 relais Numéro du ...
Q5 Gas Sensor Carbon Dioxide 05000 ppm Infrared 420mA 210V Modbus Rs485 standard Please Log In. Special Order. UOM : EA ...
carbon dioxide c02 co2 transmitter 5000 PPM 4 20mA output,transmitter 5000 PPM 4 20mA output carbon dioxide c02 co2, V0 refer toUL94, IP65 refer to IEC 529 – 598/GB 700 – 86/ GB 4208,Threewire 4~20mA Current output, 4 ~ 20mA R, High precision CO2 sensor, Signal output :, Probe material Refer to GB/T 13926 , EN6100062 , EN6100063, Top Selling Products Free Shipping and Free ...
Capteur de dioxyde de carbone CO2 (gaz carbonique) 0 à 5000 ppm : Parmi les gaz importants à mesurer dans les pièces où vivent des personnes, le dioxyde de carbone appelé aussi gaz carbonique est certainement celui qui doit être mesuré le plus précisément et le plus souvent pour déterminer la qualité de l’air intérieur et procéder à des actions pour l’éliminer (ventilation ...
CO2 SENSOR, WALL, ±5%, 05000 PPM, 420 MA, 010 VDC, 0 RELAY, NO LCD, PLASTIC ENCLOSURE, NO RATING. product family features . 24 VAC/VDC power; 010 VDC or 420 mA analog output, jumper selectable ; 05000 ppm CO2 range; Wallmount and ductsampling versions; Isolation of output and power; Compact, attractive enclosure; Optional control relay with adjustable setpoint; …
S2401CO2 Détecteur de Gaz DIOXYDE DE CARBONE (CO2) 05000 ppm, 420mA Capteur Infrarouge Boitier IP55 SMART3NC Parking et Zones non classifiées. Le détecteur de gaz S2401CO2 est utilisé pour détecter la présence de gaz Dioxyde de Carbone, CO2 en ppm. Les détecteurs de gaz SMART3 NC représentent une version non certifiée de la ligne SMART3G et sont idéaux pour les …
CDT2D44. Carbon Dioxide Transmitter, duct mount, 2000 ppm CO2 range, 4 to 20 mA / 0 to (5 or 10) VDC CO2 output temperature output. CDT2D4A. Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and 10K Ohm Type III thermistor temperature output. CDT2D4B.
carbon dioxide c02 co2 transmitter 5000 PPM 4 20mA output,c02 co2 transmitter 5000 PPM 4 20mA output carbon dioxide,Threewire 4~20mA Current output, 4 ~ 20mA R, High precision CO2 sensor, Signal output :, Probe material Refer to GB/T 13926 , EN6100062 , EN6100063, V0 refer toUL94, IP65 refer to IEC 529 – 598/GB 700 – 86/ GB transmitter 5000 PPM 4 20mA output carbon ...